Analisis Sistem Kerja UPS (Uninterruptible Power Supply) Power Scale 200 kVA Terminal Bandara PT. Angkasa Pura II (Persero)

Analysis Of The 200 Kva Power In UPS (Unintrruptible Power Scale) System at The Airport Terminal Of PT. Angkasa Pura II (Persero)

Authors

  • Aldo Lorenza Uln

DOI:

https://doi.org/10.57152/ijeere.v1i1.70

Keywords:

Power Electronics, Uninterruptible Power Scale

Abstract

The higher the level of electricity consumption, the PLN (State Power Plant) as a provider of electricity and
as a national electricity energy manager has the obligation to meet the national electrical energy needs
which are increasingly increasing. In order to avoid an undesirable thing, the electricity network is cut off at
the airport terminal which can endanger the safety, comfort and safety of prospective airplane passengers.
So, UPS is used as an alternative electrical energy supplier to anticipate sudden power outages while
waiting for an emergency generator to be activated (emergenci diesel generator). This report focuses on
discussing how long UPS can back up the Airport Terminal load without an emergency generator which is
done using the observation method in the field. The results of the observations in the field were found that by
using a UPS, namely: 3) The level of efficiency of the AC - AC UPS at the Airport Terminal is 95%, meaning
that the more power the source can provide by the Airport Terminal, this allows significant energy savings in
every work carried out at the airport, 5) The ability of the UPS to accommodate the transmitter system load,
which is for 34.16 minutes, this time is more than enough to switch the power source to the generator set, 6)
The UPS loads at the Airport Terminal by 60% (120 kVA is used from 200 kVA), more loads can still be
done, 7) UPS rating at the Airport Terminal has more power than the ideal UPS rating (oversizing UPS).
This is done to get a longer runtime, if there are additional tools, and not all electronic devices are backed
up by UPS
.

 

 

References

wikipedia, “Televisi Republik Indonesia” <http://id.wikipedia.org>. [diakses pada tanggal: 15 Februari 2018].

Efendi, Muhammad Ridho. 2016 . “Instalasi Potrable Microwave Link pada Out Broadcast LPP TVRI Riau”. Laporan Kerja Praktek pada Teknik Elektro Universitas Riau. Pekanbaru: 2016.

Nasiri, Adel. 2011. Power Electronics Handbook ( Ed.). Muhammad H. Rashid (ed.). Hlm.627-641.

Mohan, Ned. 2012. Power Electronics A First Course. New Jersey: John Wiley & sons, Inc.

JM Gurrero, LG De Vicuna, dan J. Uceda. 2007. “Uninterruptible power supply systems provide ptotection”. IEEE industrial elektronic Magazine, vol. 1, Issue 1, pp. 28-38.

Suryadiman, S Ahmad. April 2008. “Analisis Pengaruh UPS Terhadap Kinerja Perangkat Komputer”. Badan Operasi Sarana Penunjang-PTBN BATAN. NO.01/Tahun1. ISSN 1979-2409.

Teknik Energi Listrik, “anlisis daya/elektrik penyearah terkendali”, Penyearah

Terkendali,<http://teknikenergielektrik.blogspot.co.id/2016/04/anlisis/dayalektrik-penyearah-terkendali.html?m=1>, [diakses pada tanggal: 2 April 2018].

Syah, Budi N. 2015. Sistem Pengendalian Inverter Tiga Fasa Sebagai UPS, Komensator Harmonisa Dan Faktor Daya Menggunakan Modified Synchronous Reference Frame. Digital Repository Universitas Jember. <https://repository.unej.ac.id> [diakses pada tanggal: 19 Februar 2018].

Aslimeri, dkk. 2008. Teknik Transmisi Tenaga Listrik Jilid 1. Jakarta : Direktorat Pembinaan Sekolah Menengah Kejuruan.

Apriansyah, Doni. 2016. “Sistem Kerja UPS”. Laporan Kerja Praktek pada Teknik Elektro Politeknik NegeriSriwijaya. Palembang: 2016.

ABB GROUP. 2004. PowerScale User Manual. Switzerland.

SOP Electrical. 2018. Mechanical & Equipment Facility.

Published

2021-05-20

How to Cite

[1]
A. Lorenza, “Analisis Sistem Kerja UPS (Uninterruptible Power Supply) Power Scale 200 kVA Terminal Bandara PT. Angkasa Pura II (Persero): Analysis Of The 200 Kva Power In UPS (Unintrruptible Power Scale) System at The Airport Terminal Of PT. Angkasa Pura II (Persero) ”, IJEERE, vol. 1, no. 1, pp. 13-20, May 2021.